|Power Supply Current||Icc||-||45||85||mA  
|-
|'''AC CHARACTERISTICS'''
|-
|'''Clock Input'''||Fig 7. 
|-
|Frequency||fc||1||-||2||MHz 
|-
|Rise Time||tr||-||-||50||ns 
|-
|Fall Time||tf||-||-||50||ns 
|-
|Duty Cycle||-||25||50||85||% 
|-
|'''Bus Signals (BDIR,BC2,BC1)'''
|-
|Associative Delay Time||tao||-||-||50||ns 
|-
|'''Reset'''Fig. 8 
|-
|Reset Pulse Width||trw||500||-||-||ns 
|-
|Reset to Bus Control Delay Time||trb||100||-||-||ns 
|-
|'''A9, A8, DA7--DA0 (Address Mode)'''||Fig 9 
|-
|Address Setup Time||tas||400||-||-||ns 
|-
|Address Hold Time||tah||100||-||-||ns 
|-
|'''DA7--DA0 (Write Mode)'''||Fig. 10 
|-
|Write Data Pulse Width||tdw||500||-||10,000||ns 
|-
|Write Data Setup Time||tds||50||-||-||ns 
|-
|Write Data Hold Time||tdh||100||-||-||ns 
|-
|'''DA7--DA0 (Read Mode)'''||Fig. 11 
|-
|Read Data Access Time||tda||-||250||500||ns 
|-
|'''DA7--DA0 (Inactive Mode)'''
|-
|Tristate Delay Time||tts||-||100||200||ns 
|}
AC CHARACTERISTICS  
 
Clock Input  Fig 7. 
 
Frequency fc 1 - 2 MHz 
 
Rise Time tr - - 50 ns 
 
Fall Time tf - - 50 ns 
 
Duty Cycle - 25 50 85 % 
 
Bus Signals (BDIR,BC2,BC1)  
 
Associative Delay Time tao - - 50 ns 
 
Reset  Fig. 8 
 
Reset Pulse Width trw 500 - - ns 
 
Reset to Bus Control Delay Time trb 100 - - ns 
 
A9, A8, DA7--DA0 (Address Mode)  Fig 9 
 
Address Setup Time tas 400 - - ns 
 
Address Hold Time tah 100 - - ns 
 
DA7--DA0 (Write Mode)  Fig. 10 
 
Write Data Pulse Width tdw 500 - 10,000 ns 
 
Write Data Setup Time tds 50 - - ns 
 
Write Data Hold Time tdh 100 - - ns 
 
DA7--DA0 (Read Mode)  Fig. 11 
 
Read Data Access Time tda - 250 500 ns 
 
DA7--DA0 (Inactive Mode)  
 
Tristate Delay Time tts - 100 200 ns 
** Typical values are at ±25°C and nominal voltages 
'''Analogue Channel Output Test Curcuit'''
Analogue Channel Output Test Curcuit
 
 
== ELECTRICAL CHARACTERISTICS (AY-3-8913) ==